Chap.6 Commands
6-32
6.5.8 Emergency Stop (XPM_EMG)
Function Block Type
Details
XPM_EMG
DONE
REQ
BASE
SLOT
STAT
BOOL
BOOL
USINT
USINT
UINT
AXIS
USINT
Input
REQ : Request for executing function blocks
BASE : Setting up the numbers of the bases where
modules are equipped
SLOT : Setting up the numbers of slots where modules
are equipped
AXIS : Specifying the axis to give commands
1 ~ 4: 1axis ~ 4axis
Output
DONE : Keeping 1 after the initial operation
STAT : Outputting error No. that occurred during executing
function blocks
(1)
The
Emergency Stop command
is sent to the axis specified as AXIS of the embedded positioning.
(2) It is used when you have to stop the operation immediately due to emergency. The axis where this command is applied
will be in a stopped state.
(3) During Emergency Stop, the deceleration time is the value set in “Deceleration time at abrupt stop” of the basic
parameters of each axis.
(4) In AXIS, you can set up the axis to command and select one among 1~4. If the values other than set ones are selected,
“error 6” will occur.
Summary of Contents for XBE-DC08A
Page 124: ...Main Chapter 1 Configuration and Operation Mode of Programs 1 27 1 Memory block diagram ...
Page 504: ...Position Chap 6 Commands 6 61 6 11 Function blocks related to Servo Drive ...
Page 644: ...Positioning Chapter 8 Functions 8 91 ...
Page 727: ...Positioning Chapter 9 Positioning Error Information Solutions 9 13 ...
Page 1207: ...Appendix 2 Dimension App2 2 2 Analog Type XEC DN32UA ...
Page 1209: ...Appendix 2 Dimension App2 4 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Page 1210: ...Appendix 2 Dimension App2 5 4 Extension Cnet I F Module XBL C41A XBL C21A ...