P
o
sit
io
n
in
g
Chapter 5 Internal Memory and I/O Signal
5-11
5.2.2 Usage of I/O Signal
(1) JOG Operation
(a) Forward/Reverse Jog Signals show the direction of Jog Operation. The Jog operation shall be divided into
Forward/Reverse direction according to the On/Off signals. When Forward Jog Signal is On, it starts Forward
Operation and When Jog Signal is Off, it starts Reverse Operation. When both signals Off, it stops Jog Signals.
When both signals On, it does Forward Jog Signal.
Forward Jog Signal
Reverse Jog Signal
Jog Operation Status
On
Off
Forward Jog Operation
Off
On
Reverse Jog Operation
Off
Off
Stop
On
On
Forward Jog Operation
(b) If Jog direction is changed during Jog operation, it slows down at first and then operates as the direction it changed.
(c) According to value of Jog low/high Signals, it could operate with low/high speed. When jog low/high signals Off, it
operates with low speed and when they are ON, it operates with high speed.
(d) If you change value of low/high jog signals during Jog operation, there will be no stop and apply the speed as you
changed.
Time
Speed
JOG in
Operation
JOG Low/High
Speed Signal
Forward JOG
Signal
Reverse JOG
Signal
JOG High Speed
JOG Low Speed
JOG Low Speed
JOG High Speed
Summary of Contents for XBE-DC08A
Page 124: ...Main Chapter 1 Configuration and Operation Mode of Programs 1 27 1 Memory block diagram ...
Page 504: ...Position Chap 6 Commands 6 61 6 11 Function blocks related to Servo Drive ...
Page 644: ...Positioning Chapter 8 Functions 8 91 ...
Page 727: ...Positioning Chapter 9 Positioning Error Information Solutions 9 13 ...
Page 1207: ...Appendix 2 Dimension App2 2 2 Analog Type XEC DN32UA ...
Page 1209: ...Appendix 2 Dimension App2 4 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Page 1210: ...Appendix 2 Dimension App2 5 4 Extension Cnet I F Module XBL C41A XBL C21A ...