Note:
With audible alarm active, using the keyswitch when disarmed is the same as entering
an access code at the keypad. Using the keyswitch during the first 30 seconds of a delayed fire
alarm is the same as pressing a key at the keypad (the 90 second delay starts). Activation of a
keyswitch zone arms or disarms the system. Activation of this zone type is NOT logged nor is
the Police code transmitted. Bypassed zones of this type are not un-bypassed when the system
is disarmed. When the zone is bypassed, a zone bypass event buffer log and communication
occurs immediately, NOT when the system is armed.
*Keyswitch module not for use in UL/ULC listed installations.
–
Maintained Keyswitch Arm
Often used with a keyswitch module, turning the key (open state) arms the system. Turning the key
back (restored state) disarms the system. Tampers and faults only initiate their respective trouble
sequence.
Note:
DO NOT use for wireless zones. Activation of the zone does not log or transmit the
Police code. Bypassed zones of this type are not un-bypassed when the system is disarmed.
When the zone is bypassed, a zone bypass event buffer log and communication occurs
immediately, NOT when the system is armed.
With an audible alarm active, using the keyswitch when disarmed is the same as entering an access
code at the keypad. Activating this zone type during the first 30 seconds of a delayed fire alarm is
the same as pressing a key at the keypad (the 90 second delay starts). If left in the open state, the
system does not arm until the zone is restored and tripped again.
–
Momentary Keyswitch Disarm
Use with a keyswitch module. Activating and restoring this zone disarms the partition and silences
alarms. Tampers or faults do not disarm the zone.
Note:
Do not use as a global zone.
–
Maintained Keyswitch Disarm
Used with a maintained keyswitch. Activating this zone disarms the partition.
Tampers or faults on this zone do not disarm the partition.
–
Doorbell Zone
This zone type sounds a chime through keypads on the partition when activated. No alarms are
generated. Various chime tones can be programmed. Disabling door chime on the partition also
disables the chime on this zone.
Note:
Do not use as a global zone.
–
Push to Set (Non CP-01 panels only)
Activating this zone starts an infinite exit delay when armed according to the methods described in
the table below. To complete the arming sequence, this zone must be activated and restored. Once
done, the exit delay timer starts.
Arming Method
Infinite Exit Delay
Arming Mode
User Code
Y
Away
Keyswitch
Y
Away
Away Key
Y
Away
*0 Arm
Y
Away
*9 Arm
N
Stay
Stay Key
N
Stay
Night Key
N
Night
87
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference