• the module does not have enough power
• the module is not enrolled on the wireless receiver
Removing Modules
Enrolled modules can be deleted from the system via programming section [902]. For instructions,
.
Enroll Wireless Devices
Wireless devices are enrolled via the wireless transceiver module and Installer Programming
for a list of supported wireless devices.
Wireless devices are enrolled using one of the following methods:
Auto Enrollment
To enroll a wireless device using this method, press and hold the Enroll button on the device for
2-5 seconds until the LED lights then release the button. The alarm panel automatically recognizes
the device and the keypad displays a confirmation message. The device ID and next available zone
number are displayed. Press [*] to accept or scroll to another available zone number. Batteries
must be installed in the wireless device in order to enroll.
Various zone features are programmable depending on the type of device.
for details.
Pre-Enrollment
Pre-enrollment is a two step process. The first step requires entering each device ID ([804][001]-
[716]). Every wireless device has an ID printed on the sticker attached to the device. The format is
XXX-YYYY where:
• XXX identifies the type or model of the device
• YYYY is a short encrypted ID used by the system to identify the specific device
Pre-enrollment can be done at a remote location and using DLS/SA. The second step is to press the
enrollment button on the device, usually done on location. Installer Programming does not have to
be entered at this step. Both steps must be performed in order to complete the enrollment.
Working with Partitions
A partition is a limited area of the premises that operates independently from the other areas.
Partitioning a system can be beneficial if the property has outbuildings that need to be secured
independently of a main area or if the home has a separate apartment.
Each partition can have its own keypad or a keypad can have access to all partitions (only if all
partitions belong to the same owner). User access to partitions is controlled via access codes. A
master code can access the entire system and partitions, while a user code is limited to assigned
partitions.
Setting up a partition requires configuration of the following:
• create the partition
• define bell/siren operation
• assign keypads
• assign zones
• assign users
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual
42