Access code types
The alarm system provides the following user access code types:
Code
Add user
Delete user
Arm
Disarm
[*][5]
[*][6]
[*][8]
Installer
No
No
No
No
No
No
Yes +
Master
All*
All
Yes
Yes
Yes
Yes
No
Maintenance
No
No
Yes
Yes
No
No
No
User
No
No
Yes
Yes
No
No**
No
Supervisor
All but Master All but Master Yes
Yes
Yes
Yes
No
Duress
No
No
Yes
Yes
No
No
No
One-time user
No
No
Yes
1/day
No
No
No
+ If section [020] option 7 is on, a user must enter [*][6][Master Code][05] to give the installer
permission to access programming.
* Can only change master code if section [015] option 6 is off.
** Yes if [023] option 8 is on.
The installer and master codes are system codes that can be changed but not deleted. The other
codes are user-defined and can be added or deleted as necessary. By default, access codes have
the same partition and attribute programming as the code used to program them.
Access codes are either 4, 6 or 8 digits in length, depending on the setting of programming section
[041]. Duplicate codes are not valid.
Note:
EN50131-1 compliant systems using 1000 access codes shall set the access code to 8
digits (section [041], option 02).
Installer Code
This code provides access to Installer Programming [*][8]. The installer code can access all
partitions and perform any keypad function. This code can be programed by the installer in section
[006][001]. The default is 5555 (4-digit), 555555 (6-digit) or 55555555 (8-digit).
Note:
For EN50131-1 approved installations the installer code cannot change the master code
or any other level 3 codes. Attempting to access the master code from the installers code
generates an error tone from the system.
Master Code - Access Code [0001]
By default the master code can access all partitions and can perform any keypad function. This code
can be used to program all access codes, including the supervisor and duress codes.
If section [015] option 6 is on, the master code can only be changed by the installer via Installer
Programming.
The default is 1234 (4-digit), 123456 (6-digit) or 12345678 (8-digit).
The master code can be returned to factory default settings using Installer Programming section
[989].
Maintenance Code
The maintenance code can only be used to arm and disarm the system. It cannot bypass zones.
Use [*][9] to arm the system, cancel auto-arming, or perform [*][7] command functions. No arm/
disarm bell squawks are sounded when the maintenance code is used. The Maintenance code can
be programed by the installer in programming section [006][003]. The default is AAAA (4-digit),
AAAAAA (6-digit) or AAAAAAAA (8-digit).
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual
62