4 - Not Used
5 - I.D. Tone
ON: After the telephone number is dialed, the alarm system emits a tone (as specified by I.D.
Tone Frequency option) for 500ms every two seconds to indicate that a digital equipment call is in
progress.
OFF: I.D. tone is disabled.
6 - Tone Generated-2100Hz
ON: 2100 Hz I.D. tone.
OFF: 1300 Hz I.D. tone.
7 - 1 Hour DLS Window
ON: When DLS access is enabled ([*][6] option 5 ON), Installer Programming is accessible through
DLS or the [*][8] menu only once during a 1-hour window.
OFF: When DLS access is enabled, Installer Programming is accessible through DLS or the [*][8]
menu an unlimited number of times during a 6-hour window.
8 - FTC Audible Bell
ON: If a Failure to Communicate trouble is generated while the system is armed, the siren activates
for the length of bell time-out or until the system is disarmed.
OFF: If a Failure to Communicate trouble is generated while the alarm system is armed, the siren
does not activate but the keypad buzzer emits trouble beeps until a key is pressed.
[040] User Authentication
This feature enables the installer or master user to select one of two user authentication methods:
01 - User Code or Proximity Tag
The user can access the system by entering a valid code or by presenting a proximity tag.
02 - User Code and Proximity Tag
The user must enter a valid code and present a proximity tag whenever the system prompts for an
access code. A proximity tag is not required to enter [*][8] Installer Programming.
Note:
When this option is enabled, the proximity tag and code must belong to the same user.
[041] Access Code Digits
00 - 4-Digit Access Codes
Access codes are 4 digits long.
01 - 6-Digit Access Codes
Access codes are 6 digits long.
Note:
This setting is required for EN50131-1 compliant installations using less than 100
access codes.
02 8-Digit Access Codes
Access codes are 8 digits long.
Note:
This setting is required for EN50131-1 compliant installations using 1000 access
codes.
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference