[001]-[524] – Module Information
This read-only section is used to view the model number, software version, and hardware revision
information of the modules enrolled on the alarm system.
To view information for a specific module, scroll to the corresponding section:
[001]-[016] keypads
[101]-[115] 8-zone expansion module
[201] 8-output expansion module
[460] Alternate Communicator
[461] HSM2Host module
[501]-[504] 1A power supply module
[521]-[524] high-current output modules 1-4
[901] Installer Walk Test Mode Enable/Disable
This mode tests the operation of each detector in the system. Enter section [901] to initiate a walk
test. While in Walk Test mode, the Ready, Armed, and Trouble LED's on the keypad flash to indicate
that the test is active. When a zone is tripped during the test, a 2-second tone sounds on all system
keypads to indicate that the zone is working correctly.
After 10 minutes without zone activity, the alarm system emits 5 beeps every 10 seconds from all
keypads. After another 5 minutes of inactivity, Walk Test terminates automatically.
To manually exit walk test mode, enter [901] again.
Module Programming
Use this section to add, remove and confirm the following modules:
• 8-zone expander module (HSM2108)
• 8-output expander module (HSM2208)
• Power supply (HSM2300)
• 4-output power supply (HSM2204)
• Wireless transceiver (HSM2HOSTx)
• Audio Verification Module (HSM2955)
Once added, modules are supervised by the system.
[902] Add/Remove Modules
Modules can be enrolled automatically our manually. In either case, the serial number of the device
is used as an identifier.
Select one of the enrollment options described below.
153
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual