[860] Display Keypad Slot Number
The 2-digit slot number of the keypad being used is displayed in this read only section.
[861]-[876] Keypad Programming
Use section [861] to [876] to configure keypads 1 to 16. For information on keypad programming,
refer to the installation sheet supplied with the keypad.
Note:
For EN50131 compliant installations [861][021] options 1 and 2 must be disabled.
[899] Template Programming
Template programming allows quick programming of the minimum functions required for basic
operation. This section is used to view current template programming options and to define certain
system parameters. Press the (#) key to accept the displayed value and advance to the next option.
The following options are available:
• 5-digit Template Code: Displays the current 5-digit template programming code (default:
00000). Each digit in the code selects a set of pre-defined programming options, as described
below:
- Digit 1 - zone 1-8 definition options
- Digit 2 - system EOL options
- Digit 3 - alarm controller communications options
- Digit 4 - reporting code configurations
- Digit 5 - DLS connection options
• Central Station Telephone Number: The phone number used to contact the central monitoring
station (32 character limit).
• Central Station Account Code: The account code used in programming section [310]. This is a 4
or 6-digit entry.
• Partition Account Code: Used to identify partition-specific events. All 4 digits must be entered
in order to complete the entry.
• This account code is entered into programming section [310][001].
• DLS Access Code: The 6-digit DLS access code used in programming section [403].
• Partition 1 Entry Delay: The 3-digit entry delay duration for partition 1, in seconds, used in
programming [005][001] option 1.
• Partition 1 Exit Delay: The 3-digit exit delay duration for partition 1, in seconds, used in
programming section [005][001] option 3.
• Installer Code: The 4, 6 or 8-digit installer access code used in programming section [006][001].
For more information on template programming, .
Systems Information
[900] System Information
[000] – Control Panel Version
This read-only section contains the model number, software version, hardware revision, of the
alarm controller. For example, an entry of 1234 is read as version 12.34.
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual