Table 19: Trouble Indications
Trouble 08 – RF Delinquency Trouble:
[01]
Zone 001 - 128 RF Delinquency: No response from a wireless zone for 13 minutes. This trouble prevents arming until
acknowledged or cleared using [*][2].
[02]
Keypad 01 - 16 RF Delinquency: No response from a wireless keypad for 13 minutes.
[03]
Siren 01 - 16 RF Delinquency: No response from a wireless siren for 13 minutes.
[04]
Repeater 01 - 16 RF Delinquency: No response from a wireless repeater for 13 minutes.
Trouble 09 – Module Supervisory Trouble:
[01]
HSM2HOSTx not responding.
[02]
Keypad 01 - 16 not responding.
[04]
HSM2108 01 - 15 not responding.
[05]
HSM2300 01 - 04 not responding.
[06]
HSM2204 01 - 04 not responding.
[08]
HSM2208 01 - 16 not responding.
[09]
HSM2955 is not responding.
Trouble 10 – Module Tamper:
[01]
HSM2HOSTx Tamper.
[02]
Keypad 01 - 16 Tamper.
[04]
HSM2108 01 - 15 Tamper.
[05]
HSM2300 01 - 04 Tamper.
[06]
HSM2204 01 - 04 Tamper.
[08]
HSM2208 01 - 16 Tamper.
[09]
HSM2955 Tamper
[10]
Alt Comm Trouble: The trouble is for the Alt Comm tamper.
Trouble 11 – Communications:
[01]
TLM: Telephone line disconnected from control panel.
[02]
Receiver 01-04 FTC Trouble: Failure to communicate using programmed receiver paths.
[03]
Alt. Comm SIM Lock: SIM card has incorrect or unrecognized PIN.
[04]
Alt. Comm Cellular: Radio or SIM card failure, low signal strength detected, or cellular network fault.
[05]
Alt. Comm Ethernet: Ethernet connection unavailable. A valid IP address is either not programmed or the module was
unable to get an IP with DHCP.
[06]
Receiver 01-04 Absent: Alternate communicator unable to initialize a receiver.
[07]
Receiver 01-04 Supervision: Alternate communicator unable to communicate with a receiver.
[09]
Alt. Comm Fault: The alternate communicator has stopped responding.
[10]
Alt Comm FTC Trouble: The alternate communicator has failed to communicate an internal event not generated by the
panel.
Trouble 12 – Not Networked Troubles:
[01]
Zone 001-128 Not Networked Trouble: Generated when a zone becomes out of sync with the wireless network or has
not been synchronized with the network after enrollment.
[02]
Keypad 01-16 Not Networked Trouble: Generated when a keypad becomes out of sync with the wireless network or has
not been synchronized with the network after enrollment.
[03]
Siren 01-16 Not Networked Trouble: Generated when a siren becomes out of sync with the wireless network or has not
been synchronized with the network after enrollment.
[04]
Repeater 01-08 Not Networked Trouble: Generated when a repeater becomes out of sync with the wireless network or
has not been synchronized with the network after enrollment.
[05]
User 01 - 1000 Not Networked Trouble: Generated when a wireless key becomes out of sync with the wireless network
or has not been synchronized with the network after enrollment.
IMPORTANT!
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual