7 - Self Test Trouble
Sent when a self test trouble occurs for an outdoor PIR.
8 - Self Test Trouble Restore
Sent when a self test trouble has been restored for an outdoor PIR.
[312] Maintenance Events 2
1/2 – Installer Lead In/ Lead Out
The Installer Lead In and Lead Out reporting codes are sent when the alarm system enters and
exits Installer Programming respectively.
When Installer Programming is automatically exited after PC-Link is activated, the Installer Lead
Out event is not communicated until after the DLS session is complete.
3/4 – DLS Lead In/Lead Out
The DLS Lead In reporting code is sent:
• after DLS communication has been successfully established, but before the alarm system calls
back the downloading computer. This code is only transmitted when call back is enabled.
• on user-initiated call-up.
The DLS Lead Out reporting code is sent when a DLS session is successfully ended.
Note:
If DLS is terminated by an alarm, the DLS Lead Out reporting code is not transmitted.
5/6 – SA Lead In/Lead Out
The SA Lead In reporting code is sent:
• after SA communication has been successfully established, but before the alarm system calls
back the downloading computer. This code is only transmitted when call back is enabled.
• on user-initiated call-up.
The SA Lead Out reporting code is sent when an SA session is successfully ended. The SA Lead Out
reporting code is still sent if the session is terminated by an alarm.
Event Buffer 75% Full
Sent when the event buffer reaches a threshold of 75% without being uploaded.
[313] Maintenance Events 3
1/2 – Firmware Update Begin/was Successful
Sent when a remote firmware update is initiated/ is successfully completed.
3 - Firmware Update Fail
Sent after an unsuccessful remote firmware update.
[314] Maintenance Events 4
1/2 – Gas Trouble/Restore
Sent when a trouble occurs or is restored on a wireless gas detector.
3/4 – Heat Trouble/Restore
Sent when a heat trouble occurs or is restored on a wireless temperature detector.
5/6 – Freeze Trouble/Restore
Sent when a freeze trouble occurs or is restored on a wireless temperature detector.