Night Zone
Commonly assigned to interior motion detectors in areas accessed during the night. This zone
functions like an Interior Stay/Away zone [005] when armed using any method except the following:
If Stay armed, this zone is bypassed; if armed using [*][1], this zone is bypassed.
–
Final Door Set (Non CP-01 panels only)
This zone type does not use an exit timer (infinite exit delay). The door must be opened then closed
to complete the arming sequence. The arming method determines if infinite exit delay is applied.
See the table below.
Note:
Disable Exit Delay Termination with this zone type.
If this zone type is bypassed, the alarm system cannot be Away armed.
Arming Method
Infinite Exit Delay
Arming Mode
User Code
Y
Away
Keyswitch
Y
Away
Away Key
Y
Away
Wireless Key Away
Y
Away
*0 Arm
Y
Away
*9 Arm
N
Stay
Stay Key
N
Stay
Wireless Key Stay
N
Stay
Remote Access/SMS
-
Do Not Use
DLS Arm
N
Away
NAA Arming
N
Away
Note:
When Troubles/Open Zones Cancel Arming is enabled with this zone, any troubles or
open zones on the system cancel arming when the zone is tripped and restored.
Due to the potential energy requirements of infinite exit delay, wireless keypads MUST be powered
by a transformer.
If a wireless key is used to away arm the system, the door must still be opened then closed to
complete the arming sequence. The indoor siren will activate until the exit delay has expired.
–
24-Hour Burglary
This zone type is active at all times. It reports an alarm if the alarm system is armed or disarmed.
This zone type sounds the siren for the length of Bell time-out if the audible attribute is enabled.
24-Hour Bell/Buzzer
When the alarm system is armed and this type of zone is tripped, the siren activates for the
duration of the bell time-out. If the alarm system is disarmed when this type of zone is tripped, the
keypad buzzer activates until an access code is entered.
–
24-Hour Supervisory
This zone is active and reports alarms at all times when tripped. The siren and keypad buzzer do not
activate.
Note:
The supervision options (NC, EOL, DEOL) do not affect the functionality of this zone. The
restored state of this zone type is 5.6k, the alarm state is short and the trouble state is open.
For use with normally open contacts.
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual
84