Duress Feature
[*][5]> master code>
user 2-95> 5> 2
When this feature is
enabled, selected user
codes send a duress
reporting code to the
central station when
used to perform any
function on the system.
Section [019], option
[6] must be enabled.
Default: N
Required
Cancel Window
[377]>[002], option 6
Access to the
communications cancel
window. Minimum
duration must be 5
minutes.
Range: 005-255
Default: 005
Cancel Annunciation
[308]>[001], option 8
Access to the reporting
code for Alarm
Canceled.
A Cancel was
transmitted
Default: Enabled
Required
Cross Zoning
[042]>Selection 3,
option 002
Enables cross zoning
for entire system.
Zones can be enabled
for cross zoning via
zone attribute option 8
in sections [002][101] -
[128].
Programming required
Default: Disabled
Required
Burglary Verification
Timer
[005]>[000], option 3
Access to the
programmable Cross
Zone timer.
Range: 000-255 sec.
Default: 60 seconds
Allowed
Swinger Shutdown for
Alarms
[377]>[001], option 1
Access to the swinger
shutdown limit for
zone alarms
For all non-fire zones,
shut down at 1 to 6
trips.
Default: 2 trips
Required
(programmable)
Swinger Shutdown
Enable
[002]>[001] - [128],
option 6 ON
Access to swinger
shutdown,
transmission delay and
cross zone attributes.
Zone attribute option
6 (Swinger Shutdown
enabled) is ON.
Non-police response
zones
Default: Enabled
Allowed
24-Hr. Auto-verified
Fire
[001]>[001]-[128], Zone
type 025 ON
Access to 24-Hr. Auto-
verified Fire
Activates if Not
restored within the
specified time.
Must choose zone type
for application
Required
269
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual