[042] Verified Events
Burglary Verified Counter
This option programs the number of zone activations required to verify an alarm. Valid entries are
000 to 255.
Holdup Verification Counter
This counter determines the number of alarms that must occur within the Holdup verification
window before a confirmed Holdup alarm is logged and communicated. Zones with the holdup
verification zone attribute enabled contribute to the generation of a confirmed Holdup alarm in
conjunction with this counter and the holdup verification timer.
Burglary Verification Selection
Use this section to select one of the following burglary verification timer modes:
Mode
Description
001
Police Code
The burglary verification timer
operates in minutes.
002
Cross Zoning
The burglary verification timer
operates in seconds. The first
alarm in the sequence does not
log or communicate the alarm
or activate the bell.
003
Sequential Detection
The burglary verification timer
operates in minutes. The first
alarm in the sequence causes
an audible bell.
Partition Setup
[151]-[158] Partition Auto-Arm/Disarm
Enter section 151 to 158 for partition 1 to 8 auto-arm/disarm configuration.
[001] – Partition Auto-Arming Times
Use this section to program the time of day a partition is automatically armed. A different auto-
arming time can be programmed for each day of the week from Sunday to Saturday. Time is in 24-
hour format (HH:MM) and valid entries are from 00:00 to 23:59.
Conditions that cancel auto-arming if enabled:
• Open zones (depending on the settings of the zone)
• AC/DC troubles
• System troubles
• Any valid disarming procedure - proximity tag, access code, disarm key, etc.
[002] – Partition Auto-Disarm Times
Use this section to program the time of day a partition is disarmed. A different auto-disarming time
can be programmed for each day of the week from Sunday to Saturday. Time is in 24-hour format
(HH:MM) and valid entries are from 00:00 to 23:59.
Note:
If entry delay is active at auto-disarm time, the system does not disarm. A valid
disarming procedure is required by the user who initiated the entry delay.