[101] – Keypads
[102] – 8-zone Expander Modules
[103] – 8-output Expander Modules
[106] – HSM2Host
[108] – HSM2955
[109] – Power Supply
[110] – 4 High Current Output
1. After entering section [902], scroll to the module type you want to delete (101-110).
2. Press [*] to select the module type then scroll to the specific module you want to delete.
3. Press [*] to select the module then, when prompted, press [*] again to delete.
[903] Confirm Module
About this task:
The following sections are used to confirm enrollment of individual modules, their serial and slot
numbers, and to locate them physically:
[000] – View All Modules
[101] – Keypads
[102] – 8-zone Expander Modules
[103] – 8-output Expander Modules
[106] – HSM2Host
[108] – HSM2955
[109] – Power Supply
[110] – 4 High Current Output
To confirm a module:
1. Enter section [903]>[000] to view all enrolled modules or scroll to the module type you want
to confirm (101-110).
2. Press [*] to select the module type then scroll to the specific module you want to confirm.
Press [*] to enter Confirmation mode. The module’s serial number and slot number are
displayed on the keypad and the status LEDs on the device flash. This continues until
confirmation mode for the device is exited via the [#] key.
Note:
Keypad Blanking (section [016], option 3) must be disabled to confirm keypads.
Note:
When using an LED or ICON keypad, use the following table to match the number
displayed on the keypad to a module.
Table 23: Table 19 Module numbers when programming with an LED or ICON keypad
# displayed on keypad
Model #
Description
18
HSM2108
Neo 8 zone expander module
19
HSM2HOST
Neo PowerG wireless tranceiver
module
24
HSM2204
Neo 4 high current output
module
28
HSM2208
Neo 8 output expander module
30
HSM2300
Neo 1A power supply module
50
HS2LCD
Neo 2x16 LCD keypad
155
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual