Table 19: Trouble Indications
Trouble 01 – Service Required:
[01]
Bell Circuit Trouble: The bell circuit is open.
[02]
RF Jam: The HSM2HOSTx detected an RF Jam condition.
[03]
Aux Supply Trouble: The alarm controller, HSM2204 or HSM2300 has an overcurrent condition on Aux.
[04]
Loss of Clock: System time and date require programming.
[05]
Output 1 Fault: HSM2204 module detected an open condition on output #1.
Trouble 02 – Battery Trouble:
[01]
Panel Low Battery Trouble: The battery voltage (under load) is below 11.5V. Restores at 12.5V.
[02]
Panel No Battery: No battery connected to alarm controller.
[04]
HSM2204 01 - 04 Low Battery: HSM2204 has a battery voltage less than 11.5V.
[05]
HSM2204 01 - 04 No Battery: No battery connected to HSM2204.
[07]
HSM2300 01 - 04 Low Battery: HSM2300 has a battery voltage less than 11.5V
[08]
HSM2300 01 - 04 No Battery: No battery connected to HSM2300.
Trouble 03 – Bus Voltage:
[01]
HSM2HOSTx Bus Low Voltage: The HSM2HOSTx module has measured less than 6.3V on its Aux input.
[02]
Keypad 01 - 16 Bus Low Voltage: A hardwired keypad has a bus voltage of less than 6.9V for ICON/LCD (RF version) and
7.7V for non-RF models.
[04]
HSM2108 01 - 15 Bus Low Voltage: A zone expander has a bus voltage of less than 5.9V.
[05]
HSM2300 01 - 04 Bus Low Voltage: A power supply has a bus voltage of less than 6.9V.
[06]
HSM2204 01 - 04 Bus Low Voltage: A high current output module has a bus voltage of less than 6.9V.
[08]
HSM2208 01 - 16 Bus Low Voltage: The low current output module has detected a voltage less than 5.9V on its aux
input.
[09]
HSM2955 Bus Low Voltage: The audio module has detected a voltage less than 9.65V on its aux input.
Trouble 04 – AC Troubles:
[01]
Zone 001 - 128 AC Trouble: An AC trouble has been detected on a PGX934 PIR + Camera.
[03]
Siren 01 - 16 AC: A siren has an AC trouble.
[04]
Repeater 01 - 08 AC: A wireless repeater has an AC trouble.
[05]
HSM2300 01 - 04 AC: An HSM2300 has an AC trouble.
[06]
HSM2204 01 - 04 AC: An HSM2204 has an AC trouble.
[07]
Panel AC: The alarm controller has an AC failure condition.
Trouble 05 – Device Faults:
[01]
Zone 001 - 128: A zone is in fault. Additional information displayed on LCD keypads for the following troubles: Fire
Trouble (2-W Smoke, PGX916, PGX926), Freeze (PGX905), Self Test (PGX984), CO (PGX913), and Probe Disconnected (PGX905).
Also generated by a short on hardwired zones when DEOL is used or by a wireless supervisory fault.
[02]
Keypad 01 - 16: A wireless or hardwired keypad is in fault.
[03]
Siren 01 - 16: A siren is in fault.
[04]
Repeater 01 - 08: A wireless repeater is in fault (supervisory or loss of AC/DC).
Trouble 06 – Device Low Battery:
[01]
Zone 001- 128: Wireless zone has a low battery.
[02]
Keypad 01-16: Keypad has a low battery.
[03]
Siren 01 - 16: Siren has a low battery.
[04]
Repeater 01 - 08: Repeater has a low battery.
[05]
User 01 - 1000: Wireless Key has a low battery.
Trouble 07 – Device Tampers:
[01]
Zone 001 - 128 Tamper: A wireless or hardwired zone configured for DEOL operation is in tamper.
[02]
Keypad 01 - 16 Tamper: A hardwired or wireless keypad is in tamper.
[03]
Siren 01 - 16 Tamper: A wireless siren is in tamper.
[04]
Repeater 01 - 08 Tamper: A wireless repeater is in tamper.
[05]
Audio Station 01 - 04 Tamper: An audio station connected to an HSM2955 is in tamper.