UL/ULC Listed
enclosure
PC500C
PC5003C
CMC-1
PC4050CAR
PC5003C
PC5003C
PC4050CR
(red/
transfomer
mounted
inside)
PC5003C
Power UC1
Transformer
requirements
16.5V/40VA
(plug in type)
PTC1640U
(USA)
PTC1640CG
(CAN)
FTC1637 (cUL
listed)
16.5V/37VA
(Hardwired
type, mounted
inside the
enclosure or
outside using
electrical box)
16.5V/40VA
(hardwired
type, mounted
inside the
cabinet)
Battery
Capacity
requirements
7Ah
7Ah
14Ah (2 x 7Ah
in parallel)
14Ah (2 x 7Ah
in parallel)
7Ah
Standby Time UL: 4 hours
ULC: 24 hours
4 hours
24 hours
24 hours
12 hours
Alarm time
4 minutes
15 minutes
4 min (UL resi
fire)
5 min (Home
Health Care
and ULC Resi
Fire)
5 minutes
(Alarm
Transmission
only)
N/A
Recharging
current setting
400mA, 700mA 400mA, 700mA 400mA, 700mA 400mA, 700mA 400mA, 700mA
(*) For UL Residential Fire Installations, using hardwired CO Alarm Detectors, the maximum
discharge current shall be limited to 250mA to ensure 24h standby operation followed by 4 minute
CO alarm notification then followed by an additional 12h of CO Alarm notification.
SIA False Alarm Reduction Installations: Quick Reference
Minimum required system consists of one control unit model HS2128 or HS2064 or HS2032 or
HS2016-4 and any one of the compatible listed keypads: HS2LCDRF9, HS2LCDRFP9, HS2ICNRF9,
HS2ICNRFP9, HS2LCD, HS2LCDP, HS2ICN, HS2ICNP, HS2LED HS2TCHP.
The following wireless keys can also be used in SIA compatible installations: PG9929,
PG9939,PG9949.
Note:
For models PG9929 and PG9939, the panic/emergency key shall be disabled for SIA
compliant installations.
For a list of the default values programmed when the unit is shipped from the factory, and for other
programming information, refer to the following table.
The following optional subassembly modules also bear the SIA CP-01-2010 classification and may be
used if desired: HSM2108 zone expander, HSM2208 PGM output module, HSM2300 auxiliary power
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual
266