Valid entries are from 00 to 23 for the hours (HH) and 00 to 59 for the minutes (MM).
To disable the test transmission time of day, enter [9999] in this section.
Note:
This time should not be set for the same time as Daylight Savings time.
Note:
For UL listed installations, the default time is programmed for 04:45am. The panel will
generate a random test transmission time within a +/- 60 minute window. Any other value
programmed by the installer will not be affected.
[011] – Maximum Dialing Attempts
This section is used to program the number of dialing attempts made to each telephone number
when communicating. Valid entries are 002-005.
Note:
For UL/ULC listed installations, this value must be set to 005.
[012] – Delay Between PSTN Attempts
This programmable timer adds a delay before the next call is attempted over PSTN. Valid entries
are 000-255, with a default of 3 seconds (making a total of 8 seconds: 3-second delay + standard 5-
second dial tone search).
[013] – Delay Between Force Attempts
This programming option is used to set the length of time the alarm system waits between the first
dialing attempt and the force dial attempt.
Valid Entries are 001-255 seconds. Default is 020.
[014] – Post Dial Wait for Handshake
This option is used to program the length of time the communicator waits for a valid initial
handshake from the receiver after dialing the programmed telephone number. Valid entries are
001 to 255 seconds.
Note:
Maximum 45 seconds for UL installations.
[015] – T-Link Wait for Ack
This option is used to program the length of time the communicator waits for an acknowledge after
transmitting via IP/GS. Valid entries are 001 to 255. Default is 60 seconds.
[016] –IP/Cellular Fault Check Timer
This section is used to program the number of poll commands sent without valid poll responses
before the alarm system generates a trouble condition. The checks occur at 3-second intervals.
Valid entries are 003-255 for trouble annunciation and transmission.
The trouble restore is not delayed.
[380] Communicator Option 1
1 - Communications Enabled/Disabled
ON: (Default) The system communicator is enabled and all events with reporting codes are
reported to the monitoring station. Refer to the Telephone Number, Reporting Code and Call
Direction programming sections.
OFF: The system communicator is disabled and no events are reported to the monitoring station.
Note:
Disabling the communicator clears all FTC troubles.