UL Home Health Care Signaling Equipment
• There must be at least two keypads, one of either one of the compatible keypads models
HS2LED, HS2LCD(P), HS2ICN(P), HS2LCDRF(P)9, HS2ICNRF(P)9 and HS2TCHP .
• Each system shall be programmed to activate an audible Trouble signal within 90 seconds
upon loss of microprocessor memory.
• For UL Home Health Care installations, minimum bell time-out is 5 min.
• The HS2TCHP shall be used along with another compatible model keypad in order to provide
audible supervision for homehealth care or medical installations.
ULC Central Station Fire and Burglary Monitoring Installations
• For installation requirements, levels of security, communication modules and configurations
(Refer to the ULC Installation Information Sheet, DSC #29002157)
• Use a CSA/cUL approved transformer (hardwired connections required for Fire Monitoring)
• All tamper circuits may be connected to the same zone
Programming
The notes in the programming sections of the PowerSeries Neo Reference Manual describing the
system configurations for UL/ULC listed installations shall be implemented.
Control of the Protected Premises
In order to have a UL certificated system, the protected area shall be under the responsibility of one
ownership and management (i.e., one business under one name). This may be a group of buildings
attached or unattached with different addresses but under the responsibility of someone having
mutual interest. The person of mutual interest is not the alarm-installing company.
Note:
This does not apply to strip mall applications where each independent business must
have their own separate alarm system. e.g.,1: A commercial partitioned system that has
an office and a warehouse area in a building where each area can be armed or disarmed
independently. e.g.2: A residential system partitioned so that the garage area is armed
separately from the house. Each of the above examples is under the sole responsibility
of a single owner. The bell and DACT power supply must be in a protected area including
partitioned systems. The bell and DACT power supply must be located where it can be heard
by the person or persons responsible for maintaining the security system during the daily
arming cycle.
Bell Location
The alarm sounding device (bell) shall be located where it can be heard by the person operating the
security system during the daily arming and disarming cycle.
Protection of the Control Unit
The local control unit and the local power supply must be protected in one of the following ways:
• The control unit and audible alarm device must be in a protected area which is armed 24 hours
a day.
• Each partition must arm the area protecting the control unit and the audible alarm device
power supply. This may require duplicate protection armed by each partition. Access to this
protected area, without causing an alarm, will require that all partitions be disarmed.
• In all cases described above, the protected area for the control unit must be programmed as
not-bypassable.