111 - Keypad Buzzer Follow
PGM output activates with the keypad buzzer when triggered by the events below. The PGM output
remains active for the duration of the keypad buzzer.
• 24-hour supervisory buzzer zone alarm
• Auto-arm and no activity arming pre-alert.
• No activity arm pre-alert
• Entry delay
• Audible exit fault
• Audible exit delay
• Door chime
This PGM type does not activate for local key presses or trouble beeps.
114 - Ready to Arm
This PGM activates when the system is ready to arm (all non-force armed zones on the system are
restored). The PGM output de-activates when an access code is entered to arm the system and the
exit delay begins. This PGM operates as described during walk test mode (if all zones are restored).
115 - System Armed Status
This output activates when all selected partitions are armed (end of the exit delay) in either Stay or
Away modes. The output de-activates when the system is disarmed.
116 - Away Armed Status
This PGM switches on when the system is armed with stay/away zones activated. If the system is
armed with the stay/away zones always active, then the away output is active.
117 - Stay Armed Status
This PGM output activates if the system is armed with the stay/away zones bypassed.
120 - Away Armed with No Zone Bypasses Status
When assigned to a single partition, this PGM output activates when the system is armed with stay/
away and night zones active, and no zones are bypassed.
If assigned to multiple partitions, all partitions must be armed in away mode with no bypassed
zones before the PGM activates. If a force armable zone is violated at the time of arming, the PGM
does not activate. When the zone is restored, the PGM activates.
121-124 – Command Outputs 1-4
Command Outputs 1-4 are user-activated by entering [*] [7] [1-4] at any keypad. When an output is
activated, three acknowledgment beeps are sounded.
PGM outputs of this type can be programmed to follow a pre-defined schedule (programmed in
). Even if the output follows a schedule it can be manually turned
ON, OFF or follow the schedule through [*][7].
To select a schedule for these PGM outputs to follow,
129 - Partition Status Alarm Memory
This feature is intended to be used on a keyswitch plate, with a light controlled by this PGM to
indicate system status. When the partition is armed, the output activates (steady) at the: