![background image](http://html.mh-extra.com/html/johnson-controls/hs2016/hs2016_reference-manual_2023751226.webp)
Trouble [2] Module Battery Trouble
Press [02] to determine specific trouble
[11] HSM3204CX no battery
Enter 11 to view which HSM3204CX does
not have a battery connected.
Verify voltage measured across DC input terminals is 16-18 VAC. Replace
HSM65W power supply adapter if required.
Connect battery, remove AC power.
Verify measured voltage across Aux terminals is 12.5VDC min.
Replace battery if it is no longer able to hold a charge due to age.
[13] HSM3350 low battery 1
Enter 13 to view which HSM3350 has a
battery voltage less than 11.5V.
Verify voltage measured across DC input terminals is 16-18 VAC. Replace
HSM65W power supply adapter if required.
Connect battery, remove AC power.
Verify measured voltage across Aux terminals is 12.5VDC min.
Replace battery if it is no longer able to hold a charge due to age.
[14] HSM3350 low battery 2
Enter 14 to view which HSM3350 has a
battery voltage less than 11.5V.
Verify voltage measured across DC input terminals is 16-18 VAC. Replace
HSM65W power supply adapter if required.
Connect battery, remove AC power.
Verify measured voltage across Aux terminals is 12.5VDC min.
Replace battery if it is no longer able to hold a charge due to age.
[15 ] HSM3350 no battery 1
Enter 15 to view which HSM3350 does not
have a battery connected.
Verify battery is connected.
Ensure battery leads are connected with the right polarity.
Connect battery, remove AC power.
Verify measured voltage across Aux terminals is 12.5VDC min
[16] HSM3350 no battery 2
Enter 16 to view which HSM3350 does not
have a battery connected
Verify battery is connected.
Ensure battery leads are connected with the right polarity.
Connect battery, remove AC power.
Verify measured voltage across Aux terminals is 12.5VDC min
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual
226