Power Supply - North America
Transformer: DSC PTD1640U, PTC1640U,PTC1640UG, PTC1640CG
Primary: 120V, 60Hz Class II
Secondary: 16.5VAC, 40VA Max.
Power Supply - International
• Input ratings: 220V-240Vac, 50/60Hz, 200mA
• Transformer required, mounted in the same enclosure, permanently connected
• Transformer secondary ratings: 16.5Vac, 40VA min.
Note:
For installations using the transformer mounted inside the cabinet, replace fuse only
with the same type (20mm) rated 250V/315mA.
Regulated power supply:
• 7A regulated, supervised and integral to the control unit
• Type A as per EN50131-6 Standard
- 700mA auxiliary supply, 12V DC
- Positive temperature coefficient (PTC) for Bell, Aux+ and Battery terminals
- Reverse battery detection/protection
- Supervision for AC power and low battery
- Normal and high current battery charge options
- Supervised battery charging circuit
Current draw (panel):
• 85mA (nominal) 2A(Max)
Bell Output:
• 12V, 700mA supervised (1k Ohm) bell output (current limited at 2 amps)
• Steady, Pulsed, Temporal 3 fire, Temporal 4 CO alarm cadences
• Bell short detection (so hardware)
Aux+:
• Voltage range = 9.6V - 13.8V DC
• Current = 700mA (shared with Corbus R(ed))
• Output ripple voltage: 270mVp-p max.
• Onboard programmable outputs:
- PGM 1 - 50mA switched programmable output
- PGM 2 - 300mA current-limited switched programmable output. 2-Wire smoke detectors
(90mA current limited) are supported using this PGM
- PGM 3 - 50mA switched programmable output
- PGM 4 - 50mA switched programmable output
- Hardware PGM over current protection
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference