Figure 6: HSM2HOSTx Wiring Diagram
After you have completed the wiring, reconnect power to the security system. Board current draw:
35mA
Power Supply Wiring
The HSM2300/2204 power supply/high-current output module provides up to 1.0A of additional
current and can be used to add up to four programmable outputs (HSM2204 only) to the alarm
system.
The 4-wire Corbus connection provides communication between the module and alarm panel.
Connect the RED, BLK, YEL and GRN terminals to the Corbus terminals on the alarm controller. If O1
is not used, connect to Aux with a 1K resistor. Board current draw: 1.2A.
Figure 7: Power Supply Wiring
Keypad Wiring
To wire a keypad to the alarm controller, remove the keypad backplate (refer to the keypad
installation sheet) and connect the RED, BLK, YEL and GRN terminals to the corresponding
terminals on the alarm controller.
29
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference