Table 23: Table 19 Module numbers when programming with an LED or ICON keypad
# displayed on keypad
Model #
Description
51
HS2ICN
Neo Icon Keypad
52
HS2LCDP
Neo 2x16 LCD keypad with Prox
53
HS2ICNP
Neo Icon Keypad with Prox
56
HS2LED
Neo 16 LED keypad
57
HS2TCHP
Neo Touchscreen Keypad with
Prox
59
HS2LCDRF
Neo 2x16 LCD RFK keypad
5A
HS2ICNRF
Neo Icon RFK Keypad
5B
HS2LCDRFP
Neo 2x16 LCD RFK keypad with
Prox
5C
HS2ICNRFP
Neo Icon RFK Keypad with Prox
60
HS2LCDWF
Neo 2x16 LCD wirefree keypad
67
HS2TCHWF
Neo Touchscreen wirefree
Keypad
6B
HS2LCDWFP
Neo 2x16 LCD wirefree keypad
with Prox
6D
HS2LCDWFPV
Neo 2x16 LCD wirefree keypad
with Prox and Voice
95
HSM2955
Neo Audio alarm verification
module
96
HSM2955R
Neo Audio alarm verification
module with Recording
Testing
[904] Wireless Placement Test
This test is used to determine RF signal status for wireless devices and can be performed at a
system keypad or at the individual device. These instructions pertain to testing at the keypad. For
instructions on placement testing at the device, refer to the installation sheet included with the
wireless equipment.
The following test modes are available:
[001]-[128] Placement Test Zones 1-128
Test wireless devices individually by zone (LCD keypads only).
[521]-[528] Placement Test Repeaters 1-8
Test each enrolled wireless repeater (LCD keypads only).
[551]-[566] Placement Test Sirens 1-16
Test each enrolled wireless siren (LCD keypads only).
[601]-[632] Placement Test Wireless keys 1-32
Test individual wireless keys. Once in this section, press a button on the wireless key to begin the
test (LCD keypads only).
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual
156