Item
Specifications
Port
l
Two USB 2.0 ports and one DB15 VGA port on the front panel of
the server with up to eight 2.5-inch or ten 3.5-inch hard disks
l
Two USB 3.0 ports, one DB15 VGA port, one DB9 serial port, and
one RJ45 system management port on the rear panel
l
One internal USB 3.0 port, one internal dual-SD port, and two
internal miniSSDs (SATADOMs) for installing an OS or prebooting
an installation program
NOTE
The internal USB port cannot be used for installing a Windows OS. The server
with two internal miniSSDs (SATADOMs) and SoftRAID does not support the
installation of a virtualization OS. Use the
to check OSs that can be installed.
Fan module
Four hot-swappable fan modules, allowing one-fan failures
PSU
Two hot-swappable PSUs in redundancy mode:
l
460 W AC Platinum PSU, supporting 240 V HVDC
l
750 W AC Platinum PSU, supporting 240 V HVDC
l
750 W AC Titanium PSU
l
1200 W PSU, supporting 380 V HVDC
l
800 W PSU, supporting
–
48 V DC or
–
60 V DC
NOTE
The PSUs in one server must have the same BOM number. Use the
to check BOM numbers.
System
management
l
UEFI
l
Huawei iBMC
–
Uses an independent port.
–
Supports Simple Network Management Protocol (SNMP) and
Intelligent Platform Management Interface (IPMI).
–
Provides the GUI, virtual KVM, virtual media, Serial Over LAN
(SOL), smart power control, remote control, and hardware
monitoring features.
l
NC-SI
l
Huawei eSight management software and integration with third-party
management systems, such as VMware vCenter, Microsoft
SystemCenter, and Nagios
Security
l
Power-on password
l
Administrator password
l
TPM
l
Chassis-opening logging
l
Front bezel (optional)
The front bezel is installed on the front panel and comes with a
security lock to prevent unauthorized operations on hard disks.
RH2288 V3 Server
User Guide
2 Overview
Issue 32 (2019-03-28)
Copyright © Huawei Technologies Co., Ltd.
59