Sensor
Description
Remarks
CPU
N
VDDQ Temp
CPU VDDQ temperature
CPU1: Components in
positions U1000 and U59 on
the mainboard.
CPU 2: Components in
positions U62 and U65 on the
mainboard.
N
indicates the CPU ID. The
value is 1 or 2.
CPU
N
VRD Temp
CPU VRD temperature
CPU1: Component in position
U52 on the mainboard.
CPU 2: Component in position
U53 on the mainboard.
N
indicates the CPU ID. The
value is 1 or 2.
CPU
N
MEM Temp
CPU DIMM temperature
CPU.
N
indicates the DIMM
ID. The value is 1 or 2.
SYS 3.3V
Mainboard 3.3 V voltage
Component in position U21 on
the mainboard.
N
indicates the
value of 1 or 2.
SYS 5V
Mainboard 5.0 V voltage
SYS 12V
Mainboard 12.0 V voltage
CPU
N
VCore
1.8 V CPU voltage
CPU
N
DDR VDDQ
1.2 V DIMM voltage
CPU
N
DDR VDDQ2
RearDisk
N
Temp
Built-in disk backplane
temperature
Rear hard disk backplane.
N
indicates the rear hard disk
backplane number. The value
is 1 or 2.
RAID Temp
RAID controller card
temperature
RAID controller card
FAN
N
F Speed or
FAN
N
R Speed.
Fan speed
Fan module.
N
indicates the
fan module ID. The value
ranges from 1 to 4.
Power
Server input power
Total PSU power.
Power
N
PSU1 input power
PSU.
N
indicates the PSU ID.
The value is 1 or 2.
CPU Usage
CPU usage threshold
N/A
Memory Usage
DIMM usage threshold
N/A
CPU
N
Status
CPU status check
CPU.
N
indicates the CPU ID.
The value is 1 or 2.
RH2288 V3 Server
User Guide
11 Appendix
Issue 32 (2019-03-28)
Copyright © Huawei Technologies Co., Ltd.
300