Step 13
Loosen the screws on the right mounting ear. See step (3) in
.
Step 14
Remove the right mounting ear in the arrow direction and slowly pull the mounting ear signal
cable out of the chassis along the chassis interior surface. See step (4) in
.
Step 15
Place the removed right mounting ear in an ESD bag.
----End
7.62 Installing the Right Mounting Ear
Install a right mounting ear to replace the faulty one.
Procedure
Step 1
Wear an ESD wrist strap. For details, see
Step 2
Remove the right mounting ear to be replaced. For details, see
.
Step 3
Take the spare right mounting ear out of its ESD bag.
Step 4
Route the mounting ear signal cable through the chassis in the arrow direction. See step (1) in
Figure 7-145
Installing the right mounting ear
Step 5
Remove the adhesive backing from the signal cable and route the signal cable along the
grooves within the chassis. Bend the signal cable along its black lines. See
.
RH2288 V3 Server
User Guide
7 Replacing Parts
Issue 32 (2019-03-28)
Copyright © Huawei Technologies Co., Ltd.
259