describes the procedure for configuring the server.
Table 5-2
Procedure for configuring the server
Step
Description
Check the server.
l
Check the board versions.
l
Check for and clear server alarms.
Configure RAID.
Configure RAID for the server based on site
requirements.
NOTE
The RH2288 V3 supports the following RAID controller cards:
SR320 (LSI SAS2208), SR420 (LSI SAS2208), SR120 (LSI
SAS2308), SR130 (LSI SAS3008), SR430C (1 GB/2 GB, LSI
SAS3108), SP435 (PM8060), and SR135(PM8068).
Configure the BIOS.
Configure the server BIOS, including the boot mode,
network drive, PXE options of the flexible NIC, and
BIOS password.
Change the user password for
iBMC.
Change the default password for iBMC.
Install an OS.
.
5.3 Checking the RH2288 V3
Log in to the iBMC WebUI or CLI to check the health status of the RH2288 V3. Ensure that
its health status meets the environment requirements for software installation.
describes the default information for logging in to the RH2288
V3 iBMC WebUI or CLI. For details about the CLI, see the
.
Table 5-3
Default information
Item
Parameter
Default Value
iBMC management
network port
information
IP address and subnet
mask of the
management network
port
l
IP address: 192.168.2.100
l
Subnet mask: 255.255.255.0
iBMC management
system login
information
User name and
password
l
User name: root
l
Password: Huawei12#$
RH2288 V3 Server
User Guide
5 Configuring the RH2288 V3
Issue 32 (2019-03-28)
Copyright © Huawei Technologies Co., Ltd.
103