--------------- Riser Card INFO ----------------
BC11PERK BoardID: 0x0084
BC11PERL BoardID: 0x0085
-------------- HDD Backplane INFO --------------
BC11EHBD BoardID: 0x0079
BC11EHBD PCB: .A
BC11EHBD CPLD Version: (U3)1.02
n
CPLD Version
: indicates the current complex programmable logical device
(CPLD) version of the RH2288 V3.
n
BIOS Version
: indicates the BIOS version of the RH2288 V3.
n
Active iBMC Version
: indicates the active iBMC version of the RH2288 V3.
n
Backup iBMC Version
: indicates the backup iBMC version of the RH2288
V3.
c.
Query the health status for the RH2288 V3.
iBMC / # ipmcget -d health
System in health state
n
If the message "System in health state" is displayed, no further action is
required.
n
If an alarm is generated, clear the alarm by performing
.
d.
Query alarms for the RH2288 V3.
iBMC:/->ipmcget -d healthevents
System in health state
e.
Clear alarms. For details, see the
Huawei Rack Server Alarm Handling (iBMC)
5.4 Configuring RAID
Before configuring RAID, you need to obtain the IP address of the iBMC management
network port, and the user name and password for logging in to the iBMC WebUI. For details
about how to obtain the IP address of the management network port and how to operate the
iBMC, see the
Huawei Rack Server iBMC User Guide
.
Procedure
View the RAID controller card information on the iBMC WebUI.
1.
Log in to the iBMC WebUI.
For details, see
9.2 Logging In to the iBMC WebUI
.
2.
Choose
Information
on the menu bar and choose
Component Info
or
System Info
in
the navigation tree. The
Component Info
or
System Info
page is displayed.
3.
View the RAID controller card information, as shown in
.
RH2288 V3 Server
User Guide
5 Configuring the RH2288 V3
Issue 32 (2019-03-28)
Copyright © Huawei Technologies Co., Ltd.
107