2.7.5 Internal Cabling for 24-Disk Configuration
Internal Cabling for a Server with One RAID Controller Card
The RH2288 V3 does not support rear hard disks if it is configured with one RAID controller
card.
Figure 2-26
Internal cabling for a server with one RAID controller card
No. Description
BOM Number
1
Signal cable for connecting the indicator plate of the
right mounting ear to the mainboard (J43)
04051026
2
SAS cable for connecting Port B (J29) of the front
disk backplane to Port B of the RAID controller card
on the mainboard
04051021 (LSI
SAS3008/3108)
04051024 (LSI
SAS2308/2208)
3
SAS cable for connecting Port A (J28) of the front
disk backplane to Port A of the RAID controller card
on the mainboard
04051021 (LSI
SAS3008/3108)
04051024 (LSI
SAS2308/2208)
4
Signal cable for connecting the front disk backplane
(J1) to the mainboard (J1003)
04051052
5
Signal cable for connecting the USB plate of the left
mounting ear to the mainboard (J42)
04051006
6
Power cable for connecting the front disk backplane
(J24) to the mainboard (J30 PWR CONN1)
04150997
RH2288 V3 Server
User Guide
2 Overview
Issue 32 (2019-03-28)
Copyright © Huawei Technologies Co., Ltd.
45