Note
Only the access control device and other devices or systems (such
as door station, indoor station, master station, platform) are in
the same IP segment, the two-way audio can be performed.
Click Maintenance and Management → Device to enter the
device list.
Press CTRL and click to enter the remote configuration page.
Click Network → Linked Network Configuration and set the
master station's IP address and SIP server's IP address.
Click Save.
7.10.12 Configure Face Picture Parameters
Steps
1. Click Maintenance and Management → Device to enter the
device list.
2. Press CTRL and click to enter the remote configuration page.
3. Click Other → Face Picture Parameters to enter the
Configuring Face Picture Parameters page.
Min. Detection Width (Close to)
When the distance between the camera and the user is
short, the parameter represents the minimum percentage of
the facial width in the total width of the recognition area.
The actual percentage should be larger than the configured
value when face picture authentication. In this condition,
the device will not detect other parameters.
Pitch Angle
The maximum pitch angle when face authentication. By
default, the angle is 30°.
Yaw Angle
The maximum yaw angle when face authentication. By
default, the angle is 45°.
Min. Detection Area (Width)
When the distance between the camera and the user is long,
the parameter represents the minimum percentage of the
facial width in the total width of the recognition area.
The actual percentage should be larger than the configured
value when face picture authentication. Other percentages,
distances and angles in this table should also meet their
conditions.
Recommended Value: 14
Min. Detection Area (Height)
When the distance between the camera and the user is long,
the parameter represents the minimum percentage of the
facial height in the total height of the recognition area.
The actual percentage should be larger than the configured
value when face picture authentication. Other percentages,
distances and angles in this table should also meet their
conditions.
Recommended Value: 12
Margin (Left)
120