4.2 Wire Device
You can connect the terminal with peripherals.
The wiring diagram without secure door control unit is as follows.
Figure 4-2 Device Wiring
Note
• You should set the face recognition terminal's Wiegand
direction to "Input" to connect to a Wiegand card reader. If
connects to an access controller, you should set the Wiegand
direction to "Output" to transmit authentication information to
the access controller.
• For details about Wiegand direction settings, see Setting
Wiegand Parameters in Communication Settings.
• The suggested external power supply for door lock is 12 V, 1 A.
The suggested external power supply for the Wiegand card
reader is 12 V, 1A.
• The suggested power cable's diameter: 22 AWG. The suggested
other cable's diameter: 26 AWG.
Warning
The face recognition terminal shall adapt an external listed Class 2
power supply with surge protected function.
4.3 Wire Secure Door Control Unit
You can connect the terminal with the secure door control unit.
The wiring diagram is as follows.
13