Figure 3-12 Install Device
11. Use two supplied screws (SC-M4 × 12TP10-SUS) to secure the
device and the mounting plate.
Figure 3-13 Secure Device
Note
• The installation height here is the recommended height.
You can change it according to your actual needs.
• For easy installation, drill holes on mounting surface
according to the supplied mounting template.
4 Wiring
You can connect the RS-485 terminal with the RS-485 card reader,
connect the NC and COM terminal with the door lock, connect
the SENSOR terminal with the door contact, the BTN/GND
terminal with the exit button, connect the alarm output and input
terminal with the alarm output/input devices, and connect the
Wiegand terminal with the Wiegand card reader or the access
controller.
If connect the WIEGAND terminal with the access controller, the
face recognition terminal can transmit the authentication
information to the access controller and the access controller can
judge whether to open the door or not.
10