Before You Start
Set the access group and apply the access group to the access
control device. For details, refer to Set Access Group to Assign
Access Authorization to Persons.
Perform this task when you want to configure opening door with
first person.
Steps
1. Click Access Control → Advanced Function → First Person In
to enter the First Person In page.
2. Select an access control device in the list on the left panel.
3. Select the current mode as Enable Remaining Open after First
Person, Disable Remaining Open after First Person, or
Authorization by First Person from the drop-down list for each
access control point of the selected device.
Enable Remaining Open after First Person
The door remains open for the configured time duration
after the first person is authorized until the remain open
duration ends. If you select this mode, you should set the
remain open duration.
Note
The remain open duration should be between 0 and 1440
minutes. By default, the remain open duration is 10 minutes.
Disable Remaining Open after First Person
Disable the function of first person in, namely normal
authentication.
Authorization by First Person
All authentications (except for the authentications of super
card, super password, duress card, and duress code) are
allowed only after the first person authorization.
Note
You can authenticate by the first person again to disable the
first person mode.
4. Click Add on the First Person List panel.
5. Select person(s) in the left list and the person(s) will be add to
the selected persons as the first person(s) of the doors.
The added first person(s) will list in the First Person List
6. Optional: Select a first person from the list and click Delete to
remove the person from the first person list.
7. Click Save.
7.5.7 Configure Anti-Passback
You can set to only pass the access control point according to the
specified path and only one person could pass the access control
point after swiping the card.
Before You Start
Enable the anti-passing back function of the access control
device.
Perform this task when you want to configure the anti-passing
back for the access control device.