5. Commissioning
5−5
Festo P.BE−SFC−DC−IO−EN en 0801a
For commissioning an axis formed of the SFC−DC and a drive
(e.g. type SLTE−...), the mechanical composition must be
configured (type of drive) and a measuring reference system
(referencing and reference coordinates) must be defined. By
means of the measuring reference system, all positions are
defined and movement can be made to them, e.g. with a posi
tion set from the position set table.
·
Switch on the power supply for the SFC−DC.
When the power supply is switched on, the SFC−DC auto
matically carries out an internal check.
Warning
Danger of injury.
Faults in parametrization can cause injury to people and
damage to property. In the following cases a reference run
is absolutely essential in order to set the reference coordi
nates and the working range correctly:
during initial commissioning,
when the referencing method is changed,
after
each
time the logic voltage supply is switched on!
·
Check (if your drive has been configured at the factory)
the settings in the menu [Diagnostic].
·
Carry out parametrizing and commissioning with the con
trol panel or the Festo Configuration Tool, as described in
the following chapters and in the Festo Configuration
Tool/PlugIn help.
Explanations of reference coordinates and the working
area can be found in Section 1.1.3.
·
In order to complete commissioning note the instructions
for operation in the Festo Configuration Tool/PlugIn help
and in section 5.7.
Summary of Contents for SFC-DC series
Page 4: ...Contents and general instructions II Festo P BE SFC DC IO EN en 0801a...
Page 18: ...Contents and general instructions XVI Festo P BE SFC DC IO EN en 0801a...
Page 19: ...System summary 1 1 Festo P BE SFC DC IO EN en 0801a Chapter 1...
Page 39: ...Fitting 2 1 Festo P BE SFC DC IO EN en 0801a Chapter 2...
Page 45: ...Installation 3 1 Festo P BE SFC DC IO EN en 0801a Chapter 3...
Page 62: ...3 Installation 3 18 Festo P BE SFC DC IO EN en 0801a...
Page 63: ...Control panel only type SFC DC H2 4 1 Festo P BE SFC DC IO EN en 0801a Chapter 4...
Page 84: ...4 Control panel only type SFC DC H2 4 22 Festo P BE SFC DC IO EN en 0801a...
Page 85: ...Commissioning 5 1 Festo P BE SFC DC IO EN en 0801a Chapter 5...
Page 129: ...Diagnosis and error treatment 6 1 Festo P BE SFC DC IO EN en 0801a Chapter 6...
Page 137: ...Technical appendix A 1 Festo P BE SFC DC IO EN en 0801a Appendix A...
Page 142: ...A Technical appendix A 6 Festo P BE SFC DC IO EN en 0801a...
Page 143: ...Supplementary information B 1 Festo P BE SFC DC IO EN en 0801a Appendix B...
Page 192: ...B Supplementary information B 50 Festo P BE SFC DC IO EN en 0801a...
Page 193: ...Index C 1 Festo P BE SFC DC IO EN en 0801a Appendix C...
Page 194: ...C Index C 2 Festo P BE SFC DC IO EN en 0801a Contents C Index C 1...
Page 202: ...C Index C 10 Festo P BE SFC DC IO EN en 0801a...