4. Control panel (only type SFC−DC−...−H2−...)
4−7
Festo P.BE−SFC−DC−IO−EN en 0801a
Menu command
Manual
}
Diagnostic
Display of the system data and the currently effective settings (see chapter 4.2.2)
}
Pos. set table
Display the position set table
}
Axis parameters
Display axis parameters and data
}
System paramet.
Display system parameters and data
}
SW information
Display the operating system version (firmware)
}
Positioning
1) 2)
Reference run and positioning run for testing the position sets (see chapter 4.2.5)
}
Homing
Start reference run
1)
}
Move posit. set
Start positioning run Position set"
}
Demo posit. tab
Start positioning run Position set table"
}
Settings
1) 2)
Selection of the drive, parametrizing, programming the position sets ... (see chapter 4.2.4)
}
Axis type
}
SLTE_10_50_G04
Electric mini−slide type SLTE−10, stroke 50 mm, gear unit G04
}
yp
...
...
}
SLTE_16_150_G04
Electric mini−slide type SLTE−16, stroke 150 mm, gear unit G04
}
Axis parameters
}
Zero point
3)
Offset of axis zero point
}
p
}
SW−limit−neg
3)
Stroke limitation: Software end position, negative
}
SW−limit−pos
3)
Stroke limitation: Software end position, positive
}
SAVE...
Save parameters in EEPROM
}
Homing paramet.
}
Homing method
Selection of referencing method (stop, reference switch, etc.)
}
g p
}
Velocity v_rp
Positioning speed for searching for the reference point
}
Velocity v_zp
Positioning speed for moving to the axis zero point
}
SAVE...
Save parameters in EEPROM
}
Position set
}
Position no.
Number of the position set
(1...31)
}
}
Pos set mode
Set status: absolute or relative positioning
}
Position
3)
Target position of the position set
}
Velocity
Positioning speed of the position set
}
Acceleration
Acceleration for the position set
}
Deceleration
Braking acceleration of the position set
}
SAVE...
Save parameters in EEPROM
}
Password edit
Setting up a local password with 3 figures for the control panel (see chapter 4.2.4).
}
HMI control
1)
Presetting the device control via the control panel (see chapter 4.2.3)
}
LCD adjustment
Rotate the display in steps of 180°
1)
If necessary password protection
2)
Control interface must be deactivated, see [HMI control]: HMI=on
3)
Teach mode
Tab.4/3:
Menu commands (overview)
Summary of Contents for SFC-DC series
Page 4: ...Contents and general instructions II Festo P BE SFC DC IO EN en 0801a...
Page 18: ...Contents and general instructions XVI Festo P BE SFC DC IO EN en 0801a...
Page 19: ...System summary 1 1 Festo P BE SFC DC IO EN en 0801a Chapter 1...
Page 39: ...Fitting 2 1 Festo P BE SFC DC IO EN en 0801a Chapter 2...
Page 45: ...Installation 3 1 Festo P BE SFC DC IO EN en 0801a Chapter 3...
Page 62: ...3 Installation 3 18 Festo P BE SFC DC IO EN en 0801a...
Page 63: ...Control panel only type SFC DC H2 4 1 Festo P BE SFC DC IO EN en 0801a Chapter 4...
Page 84: ...4 Control panel only type SFC DC H2 4 22 Festo P BE SFC DC IO EN en 0801a...
Page 85: ...Commissioning 5 1 Festo P BE SFC DC IO EN en 0801a Chapter 5...
Page 129: ...Diagnosis and error treatment 6 1 Festo P BE SFC DC IO EN en 0801a Chapter 6...
Page 137: ...Technical appendix A 1 Festo P BE SFC DC IO EN en 0801a Appendix A...
Page 142: ...A Technical appendix A 6 Festo P BE SFC DC IO EN en 0801a...
Page 143: ...Supplementary information B 1 Festo P BE SFC DC IO EN en 0801a Appendix B...
Page 192: ...B Supplementary information B 50 Festo P BE SFC DC IO EN en 0801a...
Page 193: ...Index C 1 Festo P BE SFC DC IO EN en 0801a Appendix C...
Page 194: ...C Index C 2 Festo P BE SFC DC IO EN en 0801a Contents C Index C 1...
Page 202: ...C Index C 10 Festo P BE SFC DC IO EN en 0801a...