6. Diagnosis and error treatment
6−6
Festo P.BE−SFC−DC−IO−EN en 0801a
6.3
Fault messages on the display (only type SFC−DC−...−H2−...)
Messages
The following message is displayed if a positioning procedure
is aborted manually or cannot be carried out.
·
Acknowledge the message on the control panel with
<Enter> or start a new positioning procedure with the FCT
or via the control interface.
Message
Cause
MOTOR STOP
A positioning procedure has been stopped with
the key <Menu> (EMERG. STOP [Menu] ), with
the Festo Configuration Tool or via the control
interface.
Warnings
In the event of an impermissible operating temperature or an
unfavourable position of the reference switch, the SFC−DC will
display an appropriate warning. If a positioning task is run
ning, it will not be interrupted. The fault LED flashes, the
ERROR output is not reset.
Warning
Cause
HOT
TEMPERATURE
Operating temperature T > 70 °C,
or the drive will be overloaded, check the
mechanical parts, e.g. stiffness, reduce ambient
temperature.
COLD
TEMPERATURE
Operating temperature T < −10 °C,
if necessary, increase ambient temperature.
INDEX PULSE
WARNING
During the reference run:
The reference switch signal is close to the index
pulse. This can in some cases mean that no
reproducible reference position can be
determined.
·
Shift the reference switch
(a few tenths of a mm).
Summary of Contents for SFC-DC series
Page 4: ...Contents and general instructions II Festo P BE SFC DC IO EN en 0801a...
Page 18: ...Contents and general instructions XVI Festo P BE SFC DC IO EN en 0801a...
Page 19: ...System summary 1 1 Festo P BE SFC DC IO EN en 0801a Chapter 1...
Page 39: ...Fitting 2 1 Festo P BE SFC DC IO EN en 0801a Chapter 2...
Page 45: ...Installation 3 1 Festo P BE SFC DC IO EN en 0801a Chapter 3...
Page 62: ...3 Installation 3 18 Festo P BE SFC DC IO EN en 0801a...
Page 63: ...Control panel only type SFC DC H2 4 1 Festo P BE SFC DC IO EN en 0801a Chapter 4...
Page 84: ...4 Control panel only type SFC DC H2 4 22 Festo P BE SFC DC IO EN en 0801a...
Page 85: ...Commissioning 5 1 Festo P BE SFC DC IO EN en 0801a Chapter 5...
Page 129: ...Diagnosis and error treatment 6 1 Festo P BE SFC DC IO EN en 0801a Chapter 6...
Page 137: ...Technical appendix A 1 Festo P BE SFC DC IO EN en 0801a Appendix A...
Page 142: ...A Technical appendix A 6 Festo P BE SFC DC IO EN en 0801a...
Page 143: ...Supplementary information B 1 Festo P BE SFC DC IO EN en 0801a Appendix B...
Page 192: ...B Supplementary information B 50 Festo P BE SFC DC IO EN en 0801a...
Page 193: ...Index C 1 Festo P BE SFC DC IO EN en 0801a Appendix C...
Page 194: ...C Index C 2 Festo P BE SFC DC IO EN en 0801a Contents C Index C 1...
Page 202: ...C Index C 10 Festo P BE SFC DC IO EN en 0801a...