Dimensions X and Y will change depending on the position of camera mid plate and camera
size. Refer to the table below for the values.
Camera mid plate
The camera mid plate uses the mounting holes
A to D.
By using the different mounting holes, it can be
mounted to the camera base plate in the
different four positions.
Camera and C8 series Manipulator Joint #5 motion range (reference values)
The Joint #5 motion range varies depending on the mounting position of camera mid plate
and the camera you are using.
The table below shows the motion range (reference values) based on the available cameras
for this option and the mounting positions of the camera mid plate. The values in the table
may vary depending on how to secure the cables.
By changing the Y position, you can extend the distance from the end effector mounting
surface to the camera. Also, you can attach the larger end effector. However, be careful
about the Joint #5 motion range that will be limited in this case.
A
B
C
D
X
USB camera,
GigE camera
−
135to +70
°
−
135 to
+60
°
−
135 to
+45
°
−
135 to
+35
°
95.5 mm
A
B
C
D
Y
50 mm
30 mm
10 mm
−
10 mm
Direction of the Joint #5 motion
Summary of Contents for C8 Series
Page 1: ...Rev 13 EM208R4413F 6 Axis Robots C8 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C8 series Rev 13 ...
Page 8: ...vi C8 Rev 13 ...
Page 14: ...Table of Contents xii C8 Rev 13 ...
Page 16: ......
Page 31: ...Setup Operation 2 Specifications C8 Rev 13 17 2 4 Outer Dimensions Unit mm 2 4 1 C8 A701 C8 ...
Page 32: ...Setup Operation 2 Specifications 18 C8 Rev 13 2 4 2 C8 A901 C8L ...
Page 33: ...Setup Operation 2 Specifications C8 Rev 13 19 2 4 3 C8 A1401 C8XL ...
Page 49: ...Setup Operation 3 Environment and Installation C8 Rev 13 35 C8 A901 C8L ...
Page 98: ......
Page 183: ...Maintenance 4 Cable Unit C8 Rev 13 169 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 184: ...Maintenance 4 Cable Unit 170 C8 Rev 13 ...
Page 185: ...Maintenance 4 Cable Unit C8 Rev 13 171 ...
Page 186: ...Maintenance 4 Cable Unit 172 C8 Rev 13 4 2 2 Power Cable C8 A701 C8 C8 A901 C8L ...
Page 187: ...Maintenance 4 Cable Unit C8 Rev 13 173 C8 A1401 C8XL ...
Page 188: ...Maintenance 4 Cable Unit 174 C8 Rev 13 C8 A701 C8 C8 A901 C8L C8 A1401 C8XL ...