Setup & Operation 5. Motion Range
66
C8 Rev.13
C8-A1401***(C8XL)
Remove the mechanical stop installed as standard and install the adjustable mechanical stop
(C8XL_J2). (Joint #2 standard motion range
−
135 to +55
°
)
Hexagon socket head cap bolt M10×35×2 bolts
Tightening torque
32.0 ± 1.6 N·m (326 ± 16 kgf·cm)
d
e
d
e
Angle (
°
)
−
125, +45
−
135, +55
Pulse(pulse)
C8-A1401*** (C8XL)
−
9830500
+3538980
−
10616940
+4325420
Adjustable
mechanical stop (C8XL_J2)
Applied
Applied (standard)
5.2.3 Motion Range Setting of Joint #3
Remove the mechanical stop installed as standard and install the adjustable mechanical stop
(J3). (Joint #3 standard motion range
−
61 to +202
°
)
Hexagon socket head cap bolt M6×15×2 bolts
Tightening torque
13.0 ± 0.6 N·m (133 ± 6 kgf·cm)
f
g
f
g
Angle (
°
)
−
51, +192
−
61, +202
Pulse(pulse)
C8-A701*** (C8)
−
1485483
+5592406
−
1776754
+5883677
C8-A901*** (C8L)
−
1856859
+6990528
−
2220949
+7354618
C8-A1401*** (C8XL)
−
3342336
+12582912
−
3997696
+13238272
Adjustable mechanical stop (J3)
Applied
Applied (standard)
Summary of Contents for C8 Series
Page 1: ...Rev 13 EM208R4413F 6 Axis Robots C8 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C8 series Rev 13 ...
Page 8: ...vi C8 Rev 13 ...
Page 14: ...Table of Contents xii C8 Rev 13 ...
Page 16: ......
Page 31: ...Setup Operation 2 Specifications C8 Rev 13 17 2 4 Outer Dimensions Unit mm 2 4 1 C8 A701 C8 ...
Page 32: ...Setup Operation 2 Specifications 18 C8 Rev 13 2 4 2 C8 A901 C8L ...
Page 33: ...Setup Operation 2 Specifications C8 Rev 13 19 2 4 3 C8 A1401 C8XL ...
Page 49: ...Setup Operation 3 Environment and Installation C8 Rev 13 35 C8 A901 C8L ...
Page 98: ......
Page 183: ...Maintenance 4 Cable Unit C8 Rev 13 169 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 184: ...Maintenance 4 Cable Unit 170 C8 Rev 13 ...
Page 185: ...Maintenance 4 Cable Unit C8 Rev 13 171 ...
Page 186: ...Maintenance 4 Cable Unit 172 C8 Rev 13 4 2 2 Power Cable C8 A701 C8 C8 A901 C8L ...
Page 187: ...Maintenance 4 Cable Unit C8 Rev 13 173 C8 A1401 C8XL ...
Page 188: ...Maintenance 4 Cable Unit 174 C8 Rev 13 C8 A701 C8 C8 A901 C8L C8 A1401 C8XL ...