Setup & Operation 5. Motion Range
64
C8 Rev.13
5.2 Motion Range Setting by Mechanical Stops
Using the adjustable mechanical stops physically limits the absolute area that the
Manipulator can move.
Be sure to turn OFF the Manipulator in advance.
Use bolts conforming to the specified length and surface processing (ex:
nickel plating
) with
high corrosion resistance.
Specify the pulse range again after changing the position of the mechanical stop.
For details on the pulse range setting, refer to the
Setup & Operation 5.1 Motion Range
Setting by Pulse Range (for All Arms)
.
Be sure to set the pulse range not to exceed the setting angles of the mechanical stop.
5.2.1 Motion Range Setting of Joint #1
Install the adjustable mechanical stop (J1) to the threaded hole corresponding to the angle
you want to set.
Normally the mechanical stop is not installed.
Hexagon socket head cap bolt M12×30×2 bolts
Tightening torque
42.0 ± 2.1N·m (428 ± 21 kgf·cm)
a
b
c
a
b
c
Angle (
°
)
−
145, +110
−
110, +145
±
240
Pulse (pulse)
C8-A701*** (C8)
−
5743867
+4357416
−
4357416
+5743867
±
9507090
C8-A901*** (C8L)
−
6461925
+4902150
−
4902150
+6461925
±
10695600
C8-A1401*** (C8XL)
−
9507650
+7212700
−
7212700
+9507650
±
15736800
Adjustable mechanical stop (J1)
Applied
Applied
Not applied
(standard)
Summary of Contents for C8 Series
Page 1: ...Rev 13 EM208R4413F 6 Axis Robots C8 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C8 series Rev 13 ...
Page 8: ...vi C8 Rev 13 ...
Page 14: ...Table of Contents xii C8 Rev 13 ...
Page 16: ......
Page 31: ...Setup Operation 2 Specifications C8 Rev 13 17 2 4 Outer Dimensions Unit mm 2 4 1 C8 A701 C8 ...
Page 32: ...Setup Operation 2 Specifications 18 C8 Rev 13 2 4 2 C8 A901 C8L ...
Page 33: ...Setup Operation 2 Specifications C8 Rev 13 19 2 4 3 C8 A1401 C8XL ...
Page 49: ...Setup Operation 3 Environment and Installation C8 Rev 13 35 C8 A901 C8L ...
Page 98: ......
Page 183: ...Maintenance 4 Cable Unit C8 Rev 13 169 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 184: ...Maintenance 4 Cable Unit 170 C8 Rev 13 ...
Page 185: ...Maintenance 4 Cable Unit C8 Rev 13 171 ...
Page 186: ...Maintenance 4 Cable Unit 172 C8 Rev 13 4 2 2 Power Cable C8 A701 C8 C8 A901 C8L ...
Page 187: ...Maintenance 4 Cable Unit C8 Rev 13 173 C8 A1401 C8XL ...
Page 188: ...Maintenance 4 Cable Unit 174 C8 Rev 13 C8 A701 C8 C8 A901 C8L C8 A1401 C8XL ...