Maintenance 4. Cable Unit
160
C8 Rev.13
50.
Apply grease to the cables inside the J1 sleeve.
Grease: Krytox
Amount: Approximately 7.5g
Application position:
Between fixing section of the bracket (C1) and the mark on
the base side
51.
Fix the Arm #1 cable fixing plate to the Arm #1.
Hexagon socket head cap bolts: 2-M4
×
10
Tightening torque: 4.0
±
0.2 N·m
52.
Install the connector GS01 to the control board 1.
53.
Install the Joint #2 motor and connect the connector.
For details, refer to
Maintenance: 6.1 Joint #2 - Replacing the Motor,
Installation steps (4) and (9).
54.
Fix the two ground wire terminals to the Arm #2.
Green: Right side
Green/yellow: Left side
55.
Connect the battery connectors.
Connectors: CN3, CN6
Summary of Contents for C8 Series
Page 1: ...Rev 13 EM208R4413F 6 Axis Robots C8 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C8 series Rev 13 ...
Page 8: ...vi C8 Rev 13 ...
Page 14: ...Table of Contents xii C8 Rev 13 ...
Page 16: ......
Page 31: ...Setup Operation 2 Specifications C8 Rev 13 17 2 4 Outer Dimensions Unit mm 2 4 1 C8 A701 C8 ...
Page 32: ...Setup Operation 2 Specifications 18 C8 Rev 13 2 4 2 C8 A901 C8L ...
Page 33: ...Setup Operation 2 Specifications C8 Rev 13 19 2 4 3 C8 A1401 C8XL ...
Page 49: ...Setup Operation 3 Environment and Installation C8 Rev 13 35 C8 A901 C8L ...
Page 98: ......
Page 183: ...Maintenance 4 Cable Unit C8 Rev 13 169 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 184: ...Maintenance 4 Cable Unit 170 C8 Rev 13 ...
Page 185: ...Maintenance 4 Cable Unit C8 Rev 13 171 ...
Page 186: ...Maintenance 4 Cable Unit 172 C8 Rev 13 4 2 2 Power Cable C8 A701 C8 C8 A901 C8L ...
Page 187: ...Maintenance 4 Cable Unit C8 Rev 13 173 C8 A1401 C8XL ...
Page 188: ...Maintenance 4 Cable Unit 174 C8 Rev 13 C8 A701 C8 C8 A901 C8L C8 A1401 C8XL ...