Maintenance 5. Joint #1
C8 Rev.13
197
6.
Mount the ground wire plate (M/C cable backward).
Hexagon socket head cap bolts: 2-M4
×
10
Tightening torque: 4.0
±
0.2 N·m
7.
Install the brake power supply to the plate. Make sure to install
the brake power supply so that the cables will be in the direction as
shown in the photo.
Cross recessed head screws with washer: 2-M3×6
Tightening torque: 0.45
±
0.1 N·m
8.
Install the following connectors in accordance with the indications on the connector plates.
RJ45 connector: Ether
F-sensor connector: F-sensor
Install the ground wire to each connector. To connect the ground wire, insert it while holding the
connector by hand.
9.
Connect the M/C cable connectors.
Connector: X11, X12, X14, BR010, BR011, X010, X020, X040, LED, GS01, BT1
10.
Install the D-sub connectors in accordance with the indications on the connector plates.
Left: D-sub for brake release (with a wire marker: SW1) : B-release
Right: D-sub for user wiring (no wire marker: with a round terminal): D-sub
11.
Install two air tubes in accordance with the indications on the connector plates.
Air1: Semitransparent
Air2: Blue
Be careful not to install the air tube of wrong color.
12.
Install the connector plate (M/C cable backward).
For details, refer to
Maintenance: 3 Covers
.
NOTE
Summary of Contents for C8 Series
Page 1: ...Rev 13 EM208R4413F 6 Axis Robots C8 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C8 series Rev 13 ...
Page 8: ...vi C8 Rev 13 ...
Page 14: ...Table of Contents xii C8 Rev 13 ...
Page 16: ......
Page 31: ...Setup Operation 2 Specifications C8 Rev 13 17 2 4 Outer Dimensions Unit mm 2 4 1 C8 A701 C8 ...
Page 32: ...Setup Operation 2 Specifications 18 C8 Rev 13 2 4 2 C8 A901 C8L ...
Page 33: ...Setup Operation 2 Specifications C8 Rev 13 19 2 4 3 C8 A1401 C8XL ...
Page 49: ...Setup Operation 3 Environment and Installation C8 Rev 13 35 C8 A901 C8L ...
Page 98: ......
Page 183: ...Maintenance 4 Cable Unit C8 Rev 13 169 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 184: ...Maintenance 4 Cable Unit 170 C8 Rev 13 ...
Page 185: ...Maintenance 4 Cable Unit C8 Rev 13 171 ...
Page 186: ...Maintenance 4 Cable Unit 172 C8 Rev 13 4 2 2 Power Cable C8 A701 C8 C8 A901 C8L ...
Page 187: ...Maintenance 4 Cable Unit C8 Rev 13 173 C8 A1401 C8XL ...
Page 188: ...Maintenance 4 Cable Unit 174 C8 Rev 13 C8 A701 C8 C8 A901 C8L C8 A1401 C8XL ...