Electrical connection
Proline Prowirl F 200 PROFIBUS PA
30
Hauser
Oil-resistance
According to DIN EN 60811-2-1
Shielding
Galvanized copper-braid, opt. density approx.85 %
Cable length
5 m (16 ft), 10 m (32 ft), 20 m (65 ft), 30 m (98 ft)
Operating temperature
When mounted in a fixed position: –50 to +105 °C (–58 to +221 °F); when cable
can move freely: –25 to +105 °C (–13 to +221 °F)
1)
UV radiation may cause damage to the outer jacket of the cable. Protect the cable from exposure to sun as
much as possible.
Connecting cable (reinforced)
Cable, reinforced
2 × 2 × 0.34 mm
2
(22 AWG) PVC cable with common shield (2 pairs, pair-
stranded) and additional steel-wire braided sheath
Flame resistance
According to DIN EN 60332-1-2
Oil-resistance
According to DIN EN 60811-2-1
Shielding
Galvanized copper-braid, opt. density approx. 85%
Strain relief and
reinforcement
Steel-wire braid, galvanized
Cable length
5 m (16 ft), 10 m (32 ft), 20 m (65 ft), 30 m (98 ft)
Operating temperature
When mounted in a fixed position: –50 to +105 °C (–58 to +221 °F); when cable
can move freely: –25 to +105 °C (–13 to +221 °F)
1)
UV radiation may cause damage to the outer jacket of the cable. Protect the cable from exposure to sun as
much as possible.