Parameter overview with brief description
Parameter
Prerequisite
Description
Selection
Factory setting
Assign process variable
–
Select process variable for
totalizer.
• Volume flow
• Mass flow
• Corrected volume
flow
• Total mass flow
• Condensate mass
flow
• Energy flow
• Heat flow
difference
• Totalizer 1:
Volume flow
• Totalizer 2: Mass
flow
• Totalizer 3:
Corrected volume
flow
Unit totalizer
One of the following options is
selected in the
Assign process
variable
parameter:
• Volume flow
• Mass flow
• Corrected volume flow
• Total mass flow
• Condensate mass flow
• Energy flow
• Heat flow difference
Select the unit for the process
variable of the totalizer.
Unit choose list
m³
Control Totalizer 1 to n
In the
Assign process variable
parameter, one of the
following options is selected:
• Volume flow
• Mass flow
• Corrected volume flow
• Total mass flow
• Condensate mass flow
• Energy flow
• Heat flow difference
Control totalizer value.
• Totalize
• Reset + hold
• hold
Totalize
Totalizer operation mode
In the
Assign process variable
parameter, one of the
following options is selected:
• Volume flow
• Mass flow
• Corrected volume flow
• Total mass flow
• Condensate mass flow
• Energy flow
• Heat flow difference
Select totalizer calculation
mode.
• Net flow total
• Forward flow total
• Reverse flow total
• Last valid value
Net flow total
Failure mode
One of the following options is
selected in the
Assign process
variable
parameter:
• Volume flow
• Mass flow
• Corrected volume flow
• Total mass flow
• Condensate mass flow
• Energy flow
• Heat flow difference
Define the totalizer behavior in
the event of a device alarm.
• Stop
• Actual value
• Last valid value
Actual value
*
Visibility depends on order options or device settings