Technical data
16.1 Application
Depending on the version ordered, the measuring device can also measure potentially
explosive, flammable, poisonous and oxidizing media.
To ensure that the device remains in proper operating condition for its service life, use the
measuring device only for media against which the process-wetted materials are
sufficiently resistant.
16.2 Function and system design
Measuring principle
Vortex meters work on the principle of the
Karman vortex street
.
Measuring system
The device consists of a transmitter and a sensor.
Two device versions are available:
• Compact version – transmitter and sensor form a mechanical unit.
• Remote version - transmitter and sensor are mounted in separate locations.
For information on the structure of the device → 12
16.3 Input
Measured variable
Direct measured variables
Order code for "Sensor version; DSC sensor; measuring tube"
Option
Description
Measured variable
AA
Volume; 316L; 316L
Volume flow
AB
Volume; Alloy C22; 316L
AC
Volume; Alloy C22; Alloy C22
BA
Volume high-temperature; 316L; 316L
BB
Volume high-temperature; Alloy C22; 316L
Order code for "Sensor version; DSC sensor; measuring tube"
Option
Description
Measured variable
CA
Mass; 316L; 316L (integrated temperature measurement)
• Volume flow
• Temperature
CB
Mass; Alloy ; C22; 316L (integrated temperature measurement)
CC
Mass; Alloy C22; Alloy C22 (integrated temperature measurement)
Calculated measured variables
Order code for "Sensor version; DSC sensor; measuring tube"
Option
Description
Measured variable
AA
Volume; 316L; 316L
Under constant process conditions:
• Mass flow
• Corrected volume flow
AB
Volume; Alloy C22; 316L
Summary of Contents for Proline Prowirl F 200