Proline Prowirl F 200 PROFIBUS PA
Diagnostics and troubleshooting
Hauser
141
For access
Error
Possible causes
Solution
No write access to parameters
Hardware write protection enabled
Set the write protection switch on
main electronics module to the
OFF
position → 119.
No write access to parameters
Current user role has limited access
authorization
1. Check user role → 55.
2. Enter correct customer-specific
access code → 55.
No connection via PROFIBUS PA
PROFIBUS PA cable incorrectly
terminated
Check terminating resistor .
No connection via service interface
Incorrect configuration of USB
interface on PC or driver not
installed correctly.
Observe the documentation for the
Commubox.
FXA291: Document
"Technical Information"
TI00405C