Commissioning
Proline Prowirl F 200 PROFIBUS PA
98
Hauser
Parameter
Prerequisite
Description
Selection / User
entry
Factory setting
Mol% other gas
The following conditions are
met:
• In the
Select medium
parameter, the
Gas
option is
selected.
• In the
Select gas type
parameter, the
Gas mixture
option is selected.
• In the
Gas mixture
parameter, the
Others
option is selected.
Enter amount of substance for
the gas mixture.
0 to 100 %
0 %
Relative humidity
The following conditions are
met:
• In the
Select medium
parameter, the
Gas
option is
selected.
• In the
Select gas type
parameter, the
Air
option is
selected.
Enter humidity content of air
in %.
0 to 100 %
0 %
10.5.2 Performing external compensation
The
External compensation
submenu contains parameters which can be used to enter
external or fixed values. These values are used for internal calculations.
The
Fixed process pressure
parameter is set to the value
0 bar abs.
(ex works). In
this case, the measuring device ignores the pressure read in via PROFIBUS PA. For the
measuring device to use the external (read-in) pressure, a value > 0 bar abs. must be
entered in the
Fixed process pressure
parameter.
For a detailed description of how to calculate the mass flow and energy flow:
Navigation
"Expert" menu → Sensor → External compensation
‣
External compensation
External value
Atmospheric pressure
Delta heat calculation
Fixed density
Fixed temperature
2nd temperature delta heat
Fixed process pressure
Steam quality
Steam quality value