Parameters ASDA-A3
8-14
Revision December, 2017
8
P0.003
Analog output monitoring
Address: 0006H
0007H
Default:
0x0000
Control mode: All
Unit:
-
Setting range: 0 – 77
Format:
HEX
Data size: 16-bit
Settings:
X
Y
UZ
X: MON2
Y: MON1
UZ: reserved
MON1 and MON2
value
Description
MON1 and MON2
value
Description
0
Motor speed
(+/- 8 volts / Maximum
speed)
4
Torque command
(+/- 8 volts / Maximum
Torque command)
1
Motor torque
(+/- 8 volts / Maximum
torque)
5
VBUS voltage
(+/- 8 volts / 450V)
2
Pulse command frequency
(+8 volts / 4.5 Mpps)
6
Reserved
3
Speed command
(+/- 8 volts / Maximum
Speed command)
7
Reserved
Note: please refer to parameters P1.004 and P1.005 for the proportional setting for the analog voltage output.
For example: when you set P0.003 to 01 (MON1 is the analog output of motor speed; MON2 is the analog
output of motor torque):
MON1 output voltage =
8 x
Motor
speed
(
Maximum
speed
x
P1
.
004
100
)
(Unit: volts)
MON2 output voltage =
8 x
Motor
torque
(
Maximum
torque
x
P1
.
005
100
)
(Unit: volts)
P0.004 –
P0.007
Reserved
Summary of Contents for ASD-A3-0121
Page 13: ...Revision December 2017 This page is intentionally left blank...
Page 43: ...Installation ASDA A3 2 20 Revision December 2017 2 This page is intentionally left blank...
Page 105: ...Wiring ASDA A3 3 62 Revision December 2017 3 This page is intentionally left blank...
Page 187: ...Operation Mode ASDA A3 6 36 Revision December 2017 6 This page is intentionally left blank...
Page 467: ...Parameters ASDA A3 8 210 Revision December 2017 8 This page is intentionally left blank...
Page 577: ...Specifications ASDA A3 A 28 Revision December 2017 A This page is intentionally left blank...
Page 597: ...Accessories ASDA A3 B 20 Revision December 2017 B This page is intentionally left blank...
Page 603: ...4 Revision December 2017 This page is intentionally left blank...