Parameters ASDA-A3
8-74
Revision December, 2017
8
X: auto resonance suppression function
0: disable auto resonance suppression. After the function is disabled, the existing resonance
suppression parameter values do not change.
1: auto resonance suppression. When the servo determines it is stable, meaning that resonances
have been suppressed, and there is no other resonance, and there is no other interference that
is affecting the operation, or any other factors, then the servo automatically saves the resonance
suppression data, and resets the value to 0. If the servo is unstable, cycle the power or set this
value to 1 again for the servo to re-estimate.
Y: fixed resonance suppression parameter
In auto resonance suppression, set the Notch filters to use manual resonance suppression.
3
2
1
0
Bit
Bit
Function
Description
0
Notch 1 auto / manual setting
0: auto resonance suppression
1: manually set the first set of resonance
suppression parameters
1
Notch 2 auto / manual setting
0: auto resonance suppression
1: manually set the second set of resonance
suppression parameters
2
Notch 3 auto / manual setting
0: auto resonance suppression
1: manually set the third set of resonance
suppression parameters
3
Notch 4 auto / manual setting
0: auto resonance suppression
1: manually set the fourth set of resonance
suppression parameters
Z: fixed resonance suppression parameter
In auto resonance suppression, set the Notch filters to use manual resonance suppression.
3
2
1
0
Bit
Bit
Function
Description
0
Notch 5 auto / manual setting
0: auto resonance suppression
1: manually set the fifth set of resonance
suppression parameters
Example: if P2.047 = 0x0021, and the auto resonance suppression function is enabled, the servo
searches for the point of resonance and suppresses it. When you set Y to 2, you manually set the second
set of resonance suppression parameters. Then, if the servo finds 2 resonance points, it writes data for
the 1
st
point to the 1
st
set of resonance suppression parameters and the data for the 2
nd
point to the 3
rd
set of resonance suppression parameters. That is, it skips the 2
nd
set of parameters.
Summary of Contents for ASD-A3-0121
Page 13: ...Revision December 2017 This page is intentionally left blank...
Page 43: ...Installation ASDA A3 2 20 Revision December 2017 2 This page is intentionally left blank...
Page 105: ...Wiring ASDA A3 3 62 Revision December 2017 3 This page is intentionally left blank...
Page 187: ...Operation Mode ASDA A3 6 36 Revision December 2017 6 This page is intentionally left blank...
Page 467: ...Parameters ASDA A3 8 210 Revision December 2017 8 This page is intentionally left blank...
Page 577: ...Specifications ASDA A3 A 28 Revision December 2017 A This page is intentionally left blank...
Page 597: ...Accessories ASDA A3 B 20 Revision December 2017 B This page is intentionally left blank...
Page 603: ...4 Revision December 2017 This page is intentionally left blank...