ASDA-A3 Trial Operation and Panel Display
Revision December, 2017
4-13
4
4.4.3 Digital input diagnosis operation
You can switch to the Diagnosis mode by the following steps. When DI1 – DI10 are triggered by
the external output signal, the panel shows the corresponding signal, displayed by bit. When it
shows 1, it means the DI is on.
For example, if it shows 3FE1, E is in hexadecimal format, and is 1110 in binary format.
Then, DI6 – DI8 are ON.
S
1 1 1 1 1 1 1 1 1 0 0 0 0 1
14 13 12 11 10 9
8 7 6 5
4 3 2 1
Corresponding
DI status
Binary code
The panel displays in
hexadecimal format
(Display in hexadecimal format)
4.4.4 Digital output diagnosis operation
You can switch to the Diagnosis mode by the following steps. The output signals DO1 – DO5 are
triggered and the corresponding signal appears on the panel, displayed by bit. When it shows 1,
it means the DO is on.
For example, if it shows 1F, F is in hexadecimal format, it is 1111 in binary format.
Then, DO1 – DO4 are on.
S
0 0 0 1 1 1 1 1
5
4
3
2
1
Corresponding
DO state
Binary code
The panel displays in
hexadecimal format
(Display in hexadecimal format)
Summary of Contents for ASD-A3-0121
Page 13: ...Revision December 2017 This page is intentionally left blank...
Page 43: ...Installation ASDA A3 2 20 Revision December 2017 2 This page is intentionally left blank...
Page 105: ...Wiring ASDA A3 3 62 Revision December 2017 3 This page is intentionally left blank...
Page 187: ...Operation Mode ASDA A3 6 36 Revision December 2017 6 This page is intentionally left blank...
Page 467: ...Parameters ASDA A3 8 210 Revision December 2017 8 This page is intentionally left blank...
Page 577: ...Specifications ASDA A3 A 28 Revision December 2017 A This page is intentionally left blank...
Page 597: ...Accessories ASDA A3 B 20 Revision December 2017 B This page is intentionally left blank...
Page 603: ...4 Revision December 2017 This page is intentionally left blank...