ASDA-A3
Operation Mode
Revision December, 2017
6-19
6
6.3.5
Timing diagram for Speed mode
S4
S1
S2
Internal
register
on
off
off
on
on
off
SPD 0
SPD 1
SON
External
I/O
on
S3
External
analog
voltage or 0
Note:
1. “off” means that the contact is open while “on” means that the contact is closed.
2. When in Sz mode, the Speed command S1 = 0; when in S mode, the Speed command S1 is the
external analog voltage input.
3. In Servo On state, the command is selected by the state of SPD0 – SPD1.